Egg shaped test plugEgg shaped test plug

Egg shaped test plug - OVO

The egg shaped test plug OVO is used to close ovoid pipes and ovoid sections. These plugs are also suitable for water and air tightness tests according to DIN 4263 and NF P16-401.

These pneumatic sealing systems can be equipped with bypass tubes. Indeed, this tube ensures the passage of gas or fluids during maintenance or testing.

Moreover, it is made of a high resistance textile frame coated with vulcanized neoprene and assembled by cold gluing. The egg-shaped test plug is light, strong, resistant and quick to install. 

Avantages

Reliability

  • Low cost
  • Total tightness
  • Extremely durable

Safety

  • Secure inflation
  • Highly resistant
  • DIN 4263 and NF P16-401 Standards

Installation

  • Rapid installation

Informations détaillées

  • Material: Coated fabric 1200 daN/5 cm
  • Technique: cold glue assembly
  • Length: 600 > 2400 mm
  • Inflation: by air
  • Temperature resistance: -20 to +60°C (please contact us for any use outside of this temperature range)
  • Max. inflation pressure: 0.8 bar
  • Max. back-pressure: 0.5 bar
  • Accessory: 1 x 3/4″ valve in the center of a base

Informations techniques

Ref. Internal dimensions of the tube (Length in mm) Internal dimensions of the tube (Height in mm) Oval length (mm) Approx. weight of oval (kg) Max. inflation pressure (bar) Max. back-pressure (bar) Standard
S 30 300 450 600 20 0.8 0.5 DIN 4263
S 40 400 600 800 22 0.8 0.5 DIN 4263
S 50 500 750 1000 23 0.8 0.5 DIN 4263
S 55 550 1000 1300 24 0.8 0.5 DIN 4263
S 60 600 900 1200 26 0.8 0.5 DIN 4263
S 70 700 1050 1400 28 0.8 0.5 DIN 4263
S 80 800 1200 1600 32 0.8 0.2 DIN 4263
S 90 900 1350 1800 36 0.8 0.2 DIN 4263
S 100 1000 1500 2000 45 0.8 0.2 DIN 4263
S 120 1200 1800 2400 60 0.8 0.2 DIN 4263
T100 625 1000 1300 28 0.8 0.5 NF P16-401
T130 800 1300 1700 36 0.8 0.5 NF P16-401
T150 900 1500 2000 45 0.8 0.2 NF P16-401
T180 1080 1800 2350 60 0.8 0.2 NF P16-401
T200 1200 2000 2600 65 0.8 0.2 NF P16-401

Vous ne trouvez pas vos dimensions

Notre bureau d'études composé des meilleurs chefs de projets et de desssinateurs sauront imaginer et créer un produit sur-mesure spécialement pour vous et votre projet unique.

sur mesure

Composition / Conseils

Pre-installation tips
Inspect the pipeline and remove any rough elements (stones, deposits …). Do not inflate the stopper when it is outside the pipeline. Never place a foreign object between the walls of the pipe and the stopper.
Maintenance tips
Carefully check all the external surfaces to ensure that there are no obvious deformations (folds, bulges, or cuts). - Clean the product (using slightly soapy water but not a detergent), rinse and dry completely.
Storage advice
Deflate the stopper after each use - Store away from a source of light - Store at room temperature with a relative humidity between 40 to 70% - Ensure that the product is protected from potentially aggressive environments (corrosive products and vapours, solvents, salt water, rodents ...).

Normes / réglementations

Standards
DIN 4263 and NF P16-401
Guaranty
1 year against all manufacturing defects

Téléchargement

Fiches techniques / guides métier
  • This field is for validation purposes and should be left unchanged.

Accessoires

Inflation hose